Sounds like you are only replacing the roof membrane and not the roof deck.
How do you raise conduit 10 off a t p o roof.
30 x 89 26 7 amps we have a different take on the temperatures to use.
The primary function of the curb is to keep weather out while supporting flashing the equipment on it.
The conduit should have been attached to strucutural members that support the roof deck and not the roof deck itself.
This will take the pressure off the lifter arm.
Ideally a flashed connection would be the best practice.
Try cranking down the roof again.
Let s start with the simplest system.
Mounting conduit on existing flat roof any time you see a thin black line to the left of a paragraph in the nec it means that it s new or the wording has changed.
Self cutting or self drilling roof fasten ers can readily penetrate metals of these thicknesses.
To fix the conduit appearance the conduit should have been hidden under the solar array before the solar modules were installed.
This article will discuss the pros and cons of each approach to help you make the best decision for your project.
Also cutting and roof system removal.
Check with the local city s codes department before adding the roof.
Crank the roof up and level the camper better.
A big labor saving advantage of single ply is the large roll sizes.
Make sure the screws are not too long because they could come through the beams.
And in this one sentence lie the benefits and the detriments we face in the roof curb business everyday.
If it is not a major effort i would recommend re routing the conduit by attaching it to structural steel other than roof deck.
Prefabricated roof curbs have been in use since the roof has been utilized for something other than keeping weather out.
The roof penetration is one of the worst i ever inspected.
Although looking at it now the 2008 uses shaded sections for new or modified wording so the thin line might just be for new.
Lic conduit embedded within or directly underneath roof assemblies.
Push on the lifter arm as close to the roof as you can reach without losing your leverage away from the direction the roof is leaning.
That results in 143 with a conduit 8 above a roof and the multiplier.
By way of comparison the wall thick ness of 1 2 inch thick metallic conduit is comparable to the metal thickness of a 20 gauge steel roof deck.
For example tpo is typically available in 10 x 100 ft.
The multiplier for 90 wire at 121 is 89.
8 above a roof in a conduit has a temperature adder of 30 which results in 121.
Silicone doesn t stick to roofs and an asphalt or butyl based product should have been used.