This distance may be reduced considerably if asbestos millboard and or 28 gage sheet metal is used for wall protection.
How far above roof for wood stove poipe.
The chimney must extend at least 3 feet above the highest point where it passes through the roof and be at least 2 foot higher than any part of the building within a horizontal distance of 10 feet figure 2.
If the pipe is farther than 10 feet from the roof peak it must be 2 feet above the highest point of the roof within 10 feet.
Minimum three feet above the high side of the roof at least two feet taller than anything within ten feet the portion of the rule stating the pipe needs to be 2 feet above anything within 10 feet is where most people get confused.
Vertical blue line along the left side of the chimney in our photo.
The top of the chimney should be at least 3 ft 0 92 m above the roof surface.
The insulated chimney pipe is stacked until it reaches the required height.
All chimneys must extend 3 feet above the roof surface and 2 feet higher than any part of the building within 10 feet.
For gas vents or a type l vent this distance above the roof surface must be at least 2 ft 0 61m.
Most wood stove and factory built fireplace manufacturers and local building codes will require that the chimney must extend at least 2 feet above any portion of any structure within 10 feet measured horizontally and must extend at least 3 feet above the highest point of its roof penetration.
The termination cap is installed above this point.
This specification makes sure steep roof slopes are cleared.
The stovepipe connects with the insulated chimney at a special support box located just below the ceiling level.
If no wall protection is used the common radiant type stove or heater must be spaced out at least 36 inches from the wall.