They should be divided equally between inlet and outlet vents and they can be used in any combination that will work with your roof s design.
How many roof vent on a roof.
Federal housing authority recommends a minimum of at least 1 square foot of attic ventilation for every 300 square feet of attic floor space evenly split between intake and exhaust.
In no case should the amount of exhaust ventilation exceed the amount of intake ventilation.
Attic ventilation requirements how many attic vents your roof needs industry standard for proper attic ventilation recommends for no vapor retarder type of attic insulation no paper plastic or aluminum layer between the attic floor and insulation layer 1 sq.
Federal housing authority recommends a minimum of at least 1 square foot of attic ventilation evenly split between intake and exhaust for every 300 square feet of attic floor space.
If you want to learn more or are interested in a roofing job 1 800 hansons is at your service.
Foot of ventilation for every 150 sq.
For example if you have 1200 square feet of attic space you should need at least 4 air vents to ensure proper ventilation.
Roof vents choose one of the following products to meet the recommended exhaust nfva of 528 square inches.
Advantages of proper roofing ventilation.
Although there are many different types of roof vents to choose from ensuring you have the right number of both.
Always have a balanced ventilation system.
For the number of soffit vents in the example divide 8 square feet of ventilation needed by 0 5 for the number of rectangular vents required 16 in the example.
Thus if your attic is 450 square feet you need roof vents equaling 3 square feet.
The installation of roof vents is a crucial part of roof design because it allows for proper attic ventilation which may help prevent condensation and early aging of your roofing materials.
But if your roof has a slope greater than 6 12 this means that there will be more volume in your attic than the actual square footage.
Proper attic ventilation consists of a balance between air intake at your eaves soffits or fascias and air exhaust at or near your roof ridge.
Contact us today for a free estimate.
Federal housing authority recommends a minimum of at least 1 square foot of attic ventilation evenly split between intake and exhaust for every 300 square feet of attic floor space.
Keep in mind you should always consult with a professional roofing company when determining how many air vents your roof should have.
Some local building codes carry special considerations that take precedence.
Ventsure 4 foot strip heat moisture ridge vent.
As a general rule your roof needs 1 square foot of vent area for every 150 square feet of attic space.
How many vents will my house need.
Tips for assessing your needs.